ABL Side Mount
The side mount is used by many ABL methods and attaches to the Front. If you use Klicky or Beacon, see the Bottom Horns module for mounting options.
8mm Probe
0.4
Standard
General Notes
Mounts an 8mm inductive probe, such the Prusa Research SuperPINDA.
Type | Part | Qty |
---|---|---|
Printed | abl_8mm_probe.stl | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 1 Ea |
DIN 912 | M3 x 6mm SHCS | 3 Ea |
ABL | 8mm Inductive Probe | 1 Ea |
0.1
UHF
General Notes
Mounts an 8mm inductive probe, such the Prusa Research SuperPINDA.
Type | Part | Qty |
---|---|---|
Printed | abl_8mm_probe_uhf.stl | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 1 Ea |
DIN 912 | M3 x 6mm SHCS | 3 Ea |
ABL | 8mm Inductive Probe | 1 Ea |
BLTouch
v0.4
Standard
-35.75 mm
-8.75 mm
General Notes
(None)
Type | Part | Qty |
---|---|---|
Printed | abl_bl_touch.stl | 1 Ea |
ABL | BLTouch | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 2 Ea |
DIN 912 | M3 x 6mm SHCS | 4 Ea |
v0.4
UHF
-35.75 mm
-8.75 mm
General Notes
(None)
Type | Part | Qty |
---|---|---|
Printed | abl_bl_touch_uhf.stl | 1 Ea |
ABL | BLTouch | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 2 Ea |
DIN 912 | M3 x 6mm SHCS | 4 Ea |
CR-Touch
0.5
Standard
-38.75 mm
-11 mm
General Notes
(None)
Type | Part | Qty |
---|---|---|
Printed | abl_cr_touch.stl | 1 Ea |
ABL | Creality CR-Touch | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 4 Ea |
DIN 912 | M3 x 6mm SHCS | 4 Ea |
0.5
UHF
-38.75 mm
-11 mm
General Notes
(None)
Type | Part | Qty |
---|---|---|
Printed | abl_cr_touch_uhf.stl | 1 Ea |
ABL | Creality CR-Touch | 1 Ea |
Other Fastener | M3 x 5mm OD x 4mm L Insert | 4 Ea |
DIN 912 | M3 x 6mm SHCS | 4 Ea |